706.03 Reinforced Concrete Pipe Epoxy Coated

1. Specifications:

706.03 C&MS.

706.02

706.04

S 1074

2. Sampling and /or Inspection Requirements:

Certified Plant Sampled and Tested Materials:

Sampling is not be required. Material is tested and accepted under certification program S 1074. The Certified Supplier list is on the OMM website @ http://www.dot.state.oh.us/Divisions/ConstructionMgt/Materials/Pages/default.aspx. Materials from non -certified suppliers will not be accepted.

Inspect pipe upon delivery to the project for dimensions and condition. Type A pipe dimensions shall conform to the Table in the 706.02 Section 4. Type B pipe dimensions shall conform to the Table in the 706.04 Section 4. If the material fulfills the requirements it may be used immediately.

If the material does not fulfill the requirements, then it shall be rejected. Send a copy of TE-24 to the DET and notify OMM, Concrete Section. (Field)

Reject pipe if any of the following surface irregularities in the coating surface are found:

Air Bubbles

Blistering

Delamination

Lumping,

Sagging

Pinholing

Porosity

Markings - Where coated markings will be transferred to the coating.

3. Method of Test:

(OMM)

ASTM C 497