Item 619 FIELD OFFICE
619.01
Description
619.02 General
619.03 Method
of Measurement
619.04 Basis of
Payment
619.01 Description. This work consists of
providing, maintaining, and subsequently removing a field office for the
exclusive use of the Department for the duration of the Contract at a location
approved by the Engineer.
619.02 General. Furnish a completely functional
field office of the type specified in the Contract by the date directed by the
Engineer.
Furnish
each field office with a means for maintaining a room temperature between 68
and 80 °F (20 and 27 °C).
Furnish
electric service for each field office.
Furnish
potable hot and cold water for each field office.
Furnish
neat, sanitary, enclosed toilet accommodations for each field office.
Furnish associated lavatory and sanitary supplies. Portable facilities
may be provided with the approval of the Engineer.
For
projects requiring moisture and density control of construction materials,
provide the field office with a lockable wood or metal storage box of
sufficient size to store a nuclear density gauge and with a working electrical
connection to charge the gauge. Provide two independent lock systems: one that
locks the box the gauge is stored in; and the second one that locks the box to
the facility within which the box is housed. The second lock system may consist
of bolting the box to the office floor or wall. The storage box must be at
least 15 feet (5 meters) from any occupied work area.
For the type of field office
specified, provide the items indicated in Table 619.02-1
Item |
Type
A |
Type
B |
Type
C |
Minimum ceiling height, ft (m) |
7
(2.1) |
7
(2.1) |
7
(2.1) |
Floor space, ft² (m²) |
150
(14) |
500
(46) |
1000
(93) |
Separate enclosed room, ft² (m²) (Part of specified
floor space) |
0 (0) |
0 (0) |
100
(9) |
Telephone service & telephones [1] |
2 |
2 |
2 |
Internet service connection [5] |
1 |
1 |
1 |
Multi-Function copier that is setup for scanning, printing, faxing and copying. [2] |
1,
11×17 |
1,
11×17 |
1,
11×17 |
Calculator with tape |
1 |
2 |
3 |
Desk and chair set |
1 |
3 |
5 |
Work table, 30 ´ 72-inch (750
´ 1800 mm) |
1 |
2 |
3 |
4-drawer, legal size, lockable
metal file cabinet |
--- |
1 |
2 |
2-drawer, metal file cabinet |
1 |
2 |
2 |
Portable fire extinguishers [3] |
1 |
1 |
2 |
Plan rack [4] |
1 |
1 |
2 |
All-weather parking spaces |
8 |
16 |
20 |
[1] For
each telephone specified, provide the telephone itself, all wiring necessary to
connect the phone and multi-function copier to the phone company system, and a
working separate phone number for each telephone. Connect one phone to a
recorded answering device. For Types B and C, provide one speakerphone.
[2]
Copier must meet minimum specifications provided for each field office type.
Contractor responsible for paper supplies, copier supplies, and maintenance of
copier.
Type A:
Copy/Print Speed: 20 Pages Per Minute (Letter), 15
Pages Per Minute (Legal), 12 Pages Per Minute (Ledger) or higher
Duplex printing support
Automatic document feeder with 40 sheet duplexing document feeder
Copier Memory: 256 MB
Data Security
Kit
Paper Capacity -
250 sheet × 2 trays, 50-sheet Bypass tray
Network
Interface: 10/100Base-TX, 1000Base-TX
Analog Fax
Support Included with machine
Color Scanning
with following requirements:
Up to Up to 600 × 600 dpi
Scan Area up to 11" × 17"
Scanning Protocol Support - TCP/IP, SMTP, SMB, FTP,
POP3, NCP
File Scan Types Supported: Single Page TIFF, JPEG, PDF, Multi- Page TIFF, PDF,
and
Scanning Support for Scan-to-Email, SMB (Folder),
URL, and TWAIN
Network protocol
support for TCP/IP
Client and
Server Print Driver Support for PCL Print Drivers
Server Operating
System Support for Windows Server 2008 and Windows Server 2008 R2 (32 Bit/64
Bit)
Client Print
driver support for Windows XP/Windows 7 (Both PCL/(32
Bit and 64 Bit))
Minimum
print/copy resolution of 600 × 600 dpi
Type B:
Copy/Print Speed: 30 Pages Per Minute (Letter), 15
Pages Per Minute (Legal), 15 Pages Per Minute (Ledger) or higher
Duplex printing support
Automatic document feeder with 50 sheet duplexing document feeder
Copier Memory: 768 MB
Installed HDD:
40 GB
Data encryption
and HDD Erase Support included with machine
Internal Stapler
Support
Paper Capacity -
250 sheet × 2 trays, 50-sheet Bypass tray
Network
Interface: 10/100Base-TX, 1000Base-TX
Analog Fax
Support Included with machine
Color Scanning
with following requirements:
Up to Up to 600 × 600 dpi
Scan Area up to 11" × 17"
Scanning Protocol Support - TCP/IP, SMTP, SMB, FTP,
POP3, NCP
File Scan Types Supported: Single Page TIFF, JPEG, PDF, Multi- Page TIFF, PDF,
and OCR PDF
Scanning Support for Scan-to-Email, HDD, SMB (Folder),
URL, and TWAIN
Network protocol
support for TCP/IP
Client and
Server Print Driver Support for PCL Print Drivers
Server Operating
System Support for Windows Server 2008 and Windows Server 2008 R2 (32 Bit/64
Bit)
Client Print
driver support for Windows XP/Windows 7 (Both PCL/(32
Bit and 64 Bit))
Minimum
print/copy resolution of 600 × 600 dpi
Secure printing
with password or pin from client to copier
Type C:
Color Print/Copy/Scan
Copy/Print Speed: 30 Pages Per Minute (Letter), 15
Pages Per Minute (Legal), 15 Pages Per Minute (Ledger) or higher
Duplex printing support
Automatic
document feeder with 50 sheet duplexing document feeder
Copier Memory: 1
GB
Installed HDD:
40 GB
Data encryption
and HDD Erase Support included with machine
Internal Stapler
Support
Paper Capacity -
250 sheet × 2 trays, 50-sheet Bypass tray
Network Interface:
10/100Base-TX, 1000Base-TX
Analog Fax
Support Included with machine
Color Scanning
with following requirements:
Up to Up to 600 × 600 dpi
Scan Area up to 11" × 17"
Scanning Protocol Support - TCP/IP, SMTP, SMB, FTP,
POP3, NCP
File Scan Types Supported: Single Page TIFF, JPEG, PDF, Multi- Page TIFF, PDF,
and OCR PDF
Scanning Support for Scan-to-Email, HDD, SMB
(Folder), URL, and TWAIN
Network protocol
support for TCP/IP
Client and
Server Print Driver Support for PCL Print Drivers
Server Operating
System Support for Windows Server 2008 and Windows Server 2008 R2 (32 Bit/64
Bit)
Client Print
driver support for Windows XP/Windows 7 (Both PCL/(32
Bit and 64 Bit))
Minimum
print/copy resolution of 600 × 600 dpi
Secure printing
with password or pin from client to copier
[3] Type 2-A:10-B:C, 5-pound
(2.27 g) size
[4] Capable of handling the breakdown of 22 ´ 34-inch
(559 ´ 864 mm) sized plans into ten sections.
[5] Provide a broadband internet connection capable
of minimum download speeds as follows:
Type A: 2 Mbps download 768 Kbps upload - Network Latency less than 50
milliseconds
Type B: 5 Mbps download 1Mbps upload - Network Latency less than 50
milliseconds
Type C: 10 Mbps download 2 Mbps upload - Network Latency less than 50
milliseconds
If speeds are
not available through an individual or singular circuit, provide the highest
speed available in the area and install multiple circuits to achieve the
specified speeds. When multiple broadband services are available the
following is the preferred order: Cable, DSL, Cellular, and Wireless Radio
(Satellite Communication is not compatible with ODOT VPN
connection and will not be accepted). Supply modems capable being
configured in Bridge Mode. If a cellular network is used, provide the cellular
equipment, including software and router equipment to connect to the ODOT
provided Cisco ASA 5505 firewall. Supply ODOT with
all documentation for the broadband circuit including all username/user ids,
passwords and account information. Verify that the broadband internet
connection is active and working as specified. ODOT IT personnel will confirm
that bandwidth and network latency are compliant with the required field office
specifications. All field office Internet connections are for ODOT use only.
With
the Engineer’s written approval, the Contractor may modify the requirements for
the field office.
Maintain all utility services (e.g., electric, security,
telephone, water) for the duration of the project.
Furnish
a concrete cylinder curing box capable of holding at least eight 6 × 12 inch
(150 × 300 mm) cylinders at 73 °F (23 °C) ± 3 degrees no matter what the
ambient temperature is when constructing either portland
cement concrete pavement over 10,000 square yards (8000 m²) or over 50 cubic
yards (38 cubic meters) of bridge structure repair or replacement
concrete. The box will have a sealed lid.
619.03 Method of Measurement. The
Department will measure Field Office, Type ___ by the number of months the
office is maintained. A partial month at the end of the project will be
paid as a full month.
619.04 Basis of Payment. The
Department will pay for accepted quantities at the contract price as follows:
Item
Unit
Description
619
Month
Field Office, Type ___