701.00
Acceptance. Provide cements meeting 701.01,
701.02, 701.04, 701.05, 701.07 and 701.09
and certified according to Supplement
1028; fly ash meeting 701.13 and certified according to Supplement
1026; ground, granulated blast furnace slag meeting 701.11 and certified
according to Supplement
1034; and micro silica meeting 701.10 and certified according to Supplement
1045 without prior sampling, testing and approval by the Department. Lists for certified cement, fly ash, GGBF
slag and micro silica sources are maintained by the Laboratory.
701.01
Air-Entraining Portland Cement. Provide air-entraining portland cement
according to ASTM
C 150,
701.02
Portland Cement. Provide portland cement according to ASTM
C 150, Type II. The Gillmore time of
set and the air permeability (fineness) tests will govern.
701.04
Portland Cement. Provide portland cement according to ASTM
C 150, Type I. The Gillmore time of
set and the air permeability (fineness) tests will govern.
701.05
High Early Strength Portland Cement. Provide high early strength portland cement
according to ASTM
C 150, Type III. The Gillmore time
of set test shall govern.
701.07
Masonry Cement. Provide masonry cement according to ASTM C 91.
701.09
Slag Modified Portland Cement. Provide slag modified portland cement according to ASTM C 595, Type
I (SM).
701.10
Micro-Silica. Provide micro-silica according to ASTM C 1240. Do not use micro-silica admixtures in
dissolvable bags.
701.11
Ground Granulated Blast Furnace (GGBF) Slag. Provide ground granulated blast furnace (GGBF)
according to ASTM C 989,
Grade 100 minimum.
701.13
Fly Ash for Use in Portland Cement Concrete. Provide fly ash according to ASTM C 618,
Class C or F, except ensure a maximum loss on ignition (LOI) of 3 percent.
Flyash from
sources certified according to Supplement
1026 and with an LOI greater than 3 percent may be approved for use by the
Department if the flyash is treated with a chemical conforming to Supplement
1115.